H33

Malfunction Decision Conditions

  • The supply power is detected for its requirement by the indoor/outdoor transmission.

Malfunction Caused

  • Wrong models interconnected.
  • Wrong indoor unit and outdoor unit PCBs used.
  • Indoor unit or outdoor unit PCB defective.

Troubleshooting

When abnormality indication starts again
Check indoor and outdoor units model number
Caution For safety reason and to prevent component breakdown, always switch off the power before remove and connect the component.
Is the indoor and outdoor unit model number matched?
NO
  • Match the compatible model (follow specification)
Check indoor and outdoor PCB part number and compare if they matched part list.
YES
  • Replace the indoor and outdoor unit PCB.
NO
Change for the specified indoor or outdoor unit PCB.